DECKMA HAMBURG GmbH is a well established company, supplying Oil-in-Water Monitors and Systems to the marine and industrial markets since the early 1970's. DECKMA HAMBURG GmbH has been involved in sales, service, engineering and development of 15 ppm Bilge Alarm Monitors and Tanker Deballasting Systems from the beginning of the MARPOL regulation 73/78 for pollution prevention equipment on board of ships.
Since the early 1980's DECKMA HAMBURG GmbH introduced the well known OCD-Series of 15 ppm Bilge Alarm Monitors. More than 13.500 OCD-Bilge Alarm Monitors have been sold under the name DECKMA HAMBURG GmbH, mainly to Separator Manufacturers. In the industrial field, DECKMA HAMBURG GmbH developed "Turnkey Monitoring Systems" for the control of waste water in a variety of applications.
Demands for better measuring technique required a complete new development. In 1996 DECKMA HAMBURG GmbH launched an all new Oil-in-Water Monitor, the "OMD-7 Industrial Monitor" capable of distinguishing between the different characteristics of Oil particles, Solids particles and Water Turbidity on a continuous basis. This was the beginning of a complete new Series of Oil-in-Water Monitors - the OMD-Series. The latest version of 15ppm Bilge Alarms “OMD-24 / OMD-2008” has been launched in the market by the second half of 2012. This unit meets the latest IMO Resolution MEPC. 107(49)
Nowadays, DECKMA HAMBURG GmbH is a flexible and innovative enterprise with own Research- and Development Department, Sales and Marketing, Service and Engineering as well as manufacturing facilities for Monitors and Systems. Personal involvement of the Managing Director, the Directors and Employees are the strength of the company. A new factory located in Hamburg with 1000 m² floor space was opened in 2001 to cope with the continued business expansion, especially for the Bilge Alarm Monitor Sector.
Deckma Hamburg GmbH is the market leader of 15ppm Bilge Alarms. Up to now more than 45.000 OMD Bilge Alarms have been supplied mainly to Oily Water Separator Manufacturers worldwide.
Varosa Engineering Pvt Ltd is the official Authorized Sales and Service Agent for Deckma Hamburg GmbH in India, Sri Lanka, Bangladesh and West Africa.
As Authorized Sales and Service Station for Deckma Hamburg GmbH provides Genuine Spares, Deckma Hamburg's authorized 15ppm Calibration and Services.
Deckma Hamburg GmbH Germany manufacturer of 15ppm Bilge Alarm Monitors (MARPOL regulation 73/78 for pollution prevention equipment on board ships).
A 15ppm unit includes OCD-1, OCD-2, OCD-3, OCD-1M, OCD-2, OMD-11, OMD-21, OMD-2005, OMD-2008, OMD-24, OMD-32 etc.
The models OMD-2005, OMD-24, OMD-2008) complies IMO regulation MEPC 107(49) mainly have 2 main components consisting of the Computer Unit and Measuring Cell Unit. The Computer Unit contains the display PCB with Data logger and terminals for external connections. The Measuring Cell contains optics and electronic component and is connected with the Computer unit via plugged data cable.
We provide the required periodic calibration services for the Deckma OMD-11, Deckma OMD-21, Deckma OMD-24, Deckma OMD-2005, and Deckma OMD-2008 Oil Content Meters
DESCRIPTION | DECKMA OMD-24 | DECKMA OMD-2005 | DECKMA OMD-2008 |
---|---|---|---|
Range (measurement & indication) | 0 – 30 ppm, Trend up to 50ppm | 0 – 30 ppm, Trend up to 50ppm | 0 – 30 ppm, Trend up to 50ppm |
Range (IMO specification) | 0 – 15 ppm (according IMO regulations) | 0 – 15 ppm (according IMO regulations) | 0 – 15 ppm (according IMO regulations) |
Accuracy | According to IMO MEPC.107(49) | According to IMO MEPC.107(49) | According to IMO MEPC.107(49) |
Electrical Power Supply | 24V, AC or DC, +/-10% | 24V – 240V, AC or DC, automatic voltage adjustment | 24V – 240V, AC or DC, Automatic Voltage Selection |
Electrical Power Consumption | < 5 VA | < 15 VA | < 10 VA |
Sample | Oily water from separator outlet, 0,1 – 4 l/min | Oily water from separator outlet, 0,1 – 4 l/min | Oily water from separator outlet, 0,1 – 4 l/min |
Sample Temp. Range | +1°C to +65°C | +1°C to +65°C | +1°C to +65°C |
Alarm 1 & 2 Set Points | 1 – 15ppm (adjustable) works adjustment 15ppm | 1 – 15ppm (independently adjustable) | 1 – 15ppm (independently adjustable) |
Alarm 1 Operating Delay for Annunciation | 1 – 540 sec | 1 – 540 sec | 1 – 540 sec |
Alarm 2 Operating Delay for Control | 1 – 10 sec | 1 – 10 sec | 1 – 10 sec |
Alarm Contacts | 2 independently adjustable switchover contacts | 2 independently adjustable switchover contacts | 2 independently adjustable switchover contacts |
Alarm Contact Operation Mode | De-energized in Alarm State | De-energized in Alarm State | De-energized in Alarm State |
Alarm Contact Ratings | 3A, 240V each | 3A, 240V each | 3A, 240V each |
Alarm Output | 0 – 20 mA or 4 – 20 mA, for 0-30ppm reversible | 0 – 20 mA or 4 – 20 mA, for 0-30ppm reversible | 0 – 20 mA or 4 – 20 mA, for 0-30ppm reversible |
Display | Display Graphic Display | Display Green Graphic | Graphic Display |
Ambient Temperature | +1°C to +55°C | +1°C to +55°C | +1°C to +55°C |
Class of Protection | IP 65 | IP 65 | IP 65 |
5 ppm + 15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)
PROPERTY | VALUE |
---|---|
Range (measurement & indication) | 0 - 30 ppm, Trend up to 50ppm |
Range (IMO specification) | 0 – 15 ppm (according IMO regulations) |
Accuracy | Better Than IMO MEPC.107(49) |
Electrical Power Supply | 24V - 240V, AC or DC, Automatic Voltage Selection |
Electrical Power Consumption | < 10 VA |
Sample | Oily water from separator outlet, 0,1 - 4 l/min |
Sample Temperature Range | +1°C to +65°C |
Sample Connections | R 1/4" Female |
Alarm 1 & 2 Set Points | 1 – 15ppm (independently adjustable) |
Alarm 1 Operating Delay for Annunciation | 1 – 540 sec |
Alarm 2 Operating Delay for Control | 1 – 10 sec |
Alarm Contacts | 2 independently adjustable switchover contacts |
Alarm Contact Operation Mode | De-energized in Alarm State |
Alarm Contact Ratings | 3A, 240V each |
Alarm Output | 0 – 20 mA or 4 – 20 mA, for 0-30ppm reversible |
Display | Graphic Display |
Ambient Temperature | +1°C to +55°C |
Class of Protection | IP 65 |
Dimension | 360 x 240 x 100 mm (WxHxD) |
Weight | 5,4 kgs |
The OMD-24 Bilge Alarm Unit has been designed specifically for use in conjunction with 15 ppm oil-water separator units and has a specification and performance which exceeds the requirements of the International Maritime Organization specifications for 15ppm Bilge Alarms contained in Resolution MEPC. 107 (49).
The unit is supplied with 2 works-adjusted alarms at 15 ppm. Other set points (10 ppm or 5 ppm) are possible and can be adjusted on site at any time by using the buttons at the front panel. If an alarm set point is exceed, the alarms are visible at the front panel and the appropriate relays are switched.
In case of malfunction the System LED at the front panel will change from blinking green to permanent red. For the data logging function the unit requires an status input from the separator. Optionally a 0(4) - 20 mA (equal to 0 - 30 ppm) signal output is available for driving a recorder or external meter.
PROPERTY | VALUE |
---|---|
Range (measurement & indication) | 0 - 30 ppm, Trend up to 50ppm |
Range (IMO specification) | 0 – 15 ppm (according IMO regulations) |
Accuracy | Better Than IMO MEPC.107(49) |
Electrical Power Supply | 24V, AC or DC, +/-10% |
Electrical Power Consumption | < 5 VA |
Sample | Oily water from separator outlet, 0,1 - 4 l/min |
Sample Temperature Range | +1°C to +65°C |
Sample Connections | R 1/4" Female |
Alarm 1 & 2 Set Points | 1 - 15ppm (adjustable) works adjustment 15ppm |
Alarm 1 Operating Delay for Annunciation | 1 – 540 sec |
Alarm 2 Operating Delay for Control | 1 – 10 sec |
Alarm Contacts | 2 independently adjustable switchover contacts |
Alarm Contact Operation Mode | De-energized in Alarm State |
Alarm Contact Ratings | 3A, 240V each |
Alarm Output | 0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω |
Display | Graphic Display |
Ambient Temperature | +1°C to +55°C |
Class of Protection | IP 65 |
Dimension Computer Unit | 185 x 210 x 65 mm (WxHxD) |
Dimension Measuring Cell | 140 x 160 x 65 mm (WxHxD) |
Weight | 2,5 kgs |
The OMD-2008 EV FC MCU is equipped with a Flow Sensor. The Flow Sensor is positioned in the Drain line of the Measuring Cell.
If the flow rate through the Measuring Cell is too low, or if the sample is not flowing at all, the Instrument will go to Alarm condition and issue a “Status: Flow?” message. According to MEPC.107(49) the 15ppm Bilge Alarm has to be provided with a representative sample, i.e. the operator of the instrument is responsible to maintain a proper sample flow through the instrument. The recommended sample flow rate for Deckma instruments is approx.
2 Liters per Minute. At this flow rate, with a common setup of separator and 15ppm Bilge Alarm, it is easily possible to reliably operate the instrument, and to ensure the required short reaction time to changes in the oil content of the effluent water. The instrument does not know about the sample stream flow rate. If circumstances lead to interruptions of the sample flow, or if the sample flow is stopped completely, the portion of the sample that is in the sample glass tube will be measured continuously. The instrument will display the same measurement result for a long time, but it may fail to adequately react to changes in the overboard discharge water oil content. For many years the OMD series instruments have had a dedicated input to connect a flow switch to monitor the sample flow rate.
However, not many installation have been made with an additional flow switch. A more easy solution had to be found, a solution that does not require additional pipework, or electrical work, on site. The new OMD-2008 EV FC MCU version of the OMD-2008 instrument come with a flow sensor that measures the sample flow rate, and automatically sets the instrument into alarm condition, if a sufficient flow rate is not maintained. Constructed to make accidental flow interruptions, incorrectly closed valves, and a missing sample stream harmless events that do not lead to unlawful discharge, the OMD-2008 EV FC MCU also makes manipulation and tinkering with the instrument setup much less rewarding. Additionally for the OMD-2008 EV FC MCU instruments a Manual Cleaning Unit (MCU) is available.
This system allows to quickly clean the sample glass tube without having to open the Measuring Cell. With the MCU maintenance of the system becomes very easy, ensuring high reliability and reduced maintenance workload.
If you should require any further information, please do not hesitate to contact us directly.
PROPERTY | VALUE |
---|---|
Range | 0 – 30 ppm, Trend indication 50ppm |
Accuracy | According IMO MEPC. 107(49) |
Linearity | Better Than IMO MEPC.107(49) |
Display | Yellow Graphic Display |
Power Supply | 9 |
Alarm Points 1+2 | Adjustable between 1 - 15 ppm (Works adjustment 15 ppm) |
Alarm 1 Operating Delay | (for annunciation purpose)Adjustable between 1 – 540 sec. (Works adjustment 2 sec) |
Sample Connections | R 1/4" Female |
Alarm 1 & 2 Set Points | 1 - 15ppm (adjustable) works adjustment 15ppm |
Alarm 2 Operating Delay | (for control purposes)Adjustable between 1 – 10 sec. (Works adjustment 10 sec) |
Alarm 2 Operating Delay for Control | 1 – 10 sec |
System Fault Alarm | Red LED |
Alarm Contact Rating | Potential free 1 pole change over contacts, 3 A / 240 V |
Alarm Indication | Red LEDs |
Output Signal | 0 – 20 mA or 4 – 20 selectable active current loop, ext. Load < 150 Ohm |
Clean Water Pressure | 0-6 bar |
Sample Water Pressure | 0,1 - 6 bar |
Sample Flow | Approx. 0,6 - 3 l/min depend. to pressure |
Ambient Temperature | + 1 to + 55° C |
Sample Water Temperature | + 1 to + 65° C |
Size (Computer Unit) | 200 mm W x 200 mm H x 100 mm D |
Size (EV-FC-MCU Arrangement) | 150 mm W x 290 mm H x 140 mm D |
Degree of Protection | IP 65 |
Weight | 5,9 kg |
Deckma OMD-2005 Oil Content Meter.
The Deckma OMD-2005 Bilge Alarm Monitor was designed by Deckma Hamburg GmbH for use in conjunction with 15 ppm Oily Water Separator Systems. The performance and specifications of the OMD-2005 comply with IMO Resolution MEPC.107 (49).
The OMD-2005 is made up of 3 main components: the Computer Unit, Measuring Cell & Valve Assembly. The Computer Unit includes a memory card (data logger) that records and stores up to 18 month of data. The Measuring Cell houses the optical electronics and corresponds with the computer unit via the communication cable. The Valve Assembly is connected directly to the Measuring Cell and Computer unit and contains a special handle to sense the position of the valve.